Air Pollution Prevention and Control
Material Topics: Air pollution Control; Corresponding Sustainability Principle: Sustainable Development (GRI 2-25、3-3)
Management Approach and Elements
Importance to APC
Air quality remains an issue of public concern in the petrochemical industry. The emission of air pollutants not only impacts compliance with environmental regulations but also affects ambient air quality and public health.
Management Approach and Objectives
Through VOCs leak detection of equipment components and equipment air pollutant emission reduction improvements, APC's Linyuan Plant monitors and improves air pollutant emission quality to meet the control standards of government air pollution regulations and improve the air quality surrounding the plant area.
Strategy
- Equipment component leak inspection
- Air pollution emission improvement
- Regulatory compliance
Management Impact
Positive/Negative Impacts
Negative actual impact - Air pollution control is not implemented
Negative Remediation and Preventive Measures
- Increase the frequency of regular equipment component inspections, raising the monthly inspection points from 420 to 500.
- Add Liquid-Gas Oxidizers paired with air pollution control equipment to effectively reduce emissions of particulates, nitrogen oxides, and volatile organic compounds.
- Conduct regular monthly equipment maintenance to reduce equipment failure rates.
Management Approach Targets and Performance
2025 Targets
- Regular inspection of equipment components, inspecting 450 points per month
- Process air pollution emission improvement plan
- Air pollutant emissions per unit of product (kg/metric ton), target control values:
Nitrogen Oxides (NOx):< 0.0418
Sulfur Oxides (SOx):< 0.0458
Volatile Organic Compounds (VOCs):< 0.2214
2025 Performance
- Regular inspection of equipment components, inspecting 875 points per month(✓)
- Air pollutant emissions per unit of product (kg/metric ton):
NOx: 0.0374(✓)
SOx:0.0092(✓)
VOCs:0.1976(✓)
Short-term Targets(<3 years)
- Regular inspection of equipment components, inspecting 500 points per month
- Add Liquid-Gas Oxidizers paired with air pollution control equipment to replace old steam boilers, reducing air pollution emissions of nitrogen oxides (NOx) below 30 ppm and particulates below 10 mg/Nm3
- Air pollutant emissions per unit of product (kg/metric ton), target control values:
NOx < 0.0418;
SOx < 0.0458;
VOCs < 0.2214
Mid-to-Long-Term Targets(≧3 years)
- The Environmental Protection Section inspects 600 VOCs equipment components monthly.
- Air pollutant emissions per unit of product (kg/metric ton), 1% lower than target control values:
NOx: < 0.0376;
SOx: < 0.0412;
VOCs: < 0.1993
Evaluation of Management Approach
Effectiveness Evaluation
Commission qualified testing operators recognized by the National Environmental Research Academy to regularly test air pollutant emissions every year.
Grievance Mechanism
Environmental impact grievance channel.
Management Approach Adjustments
Group technical exchange meetings to exchange experiences on environmental pollution control technologies.
The primary air pollutants at the APC Linyuan Plant include Nitrogen Oxides (NOx), Sulfur Oxides (SOx), Volatile Organic Compounds (VOCs), and Hazardous Air Pollutants (HAPs).
NOx and SOx within the plant are mainly generated by on-site combustion equipment (such as regenerative thermal oxidizers, steam boilers, and thermal oil heaters); there are no sources of ozone-depleting substances (ODS) within the plant.
VOCs originate primarily from emissions and leakages associated with regenerative thermal oxidizers, flare stacks, storage tanks, equipment cleaning solvents, and equipment components. HAPs are mainly contributed by the raw material vinyl acetate monomer (VAM).
In addition to conducting regular testing and reporting of air pollutants, the following reduction plans have been formulated to effectively decrease air pollutant emissions:
Reduce VOCs Emissions
Every quarter, testing organizations certified by the National Environmental Research Academy are commissioned to test equipment components throughout the plant. Independent inspections of equipment components (15,000 points/month) are conducted, including replacing an old initiator pump (one unit) and replacing low-leakage valves and pumps (200 points). Due to the purchase of 2 new FID detectors (TVA-2020), spot-check capacity can reach 800 points/month, which is an increase in quantity compared to previous years.
Ethylene Recovery Process
We have implemented mutual ethylene recovery between different production lines during process shutdowns on each production line.
Off-site Underground Ethylene Pipelines Ethylene Emptying Recovery
When there is an operation issue that needs to empty the off-site underground ethylene pipelines for maintenance, we recover ethylene to each production line through the in-house ethylene recovery pipelines to reduce air pollution.
Process Waste Gas Reduction Improvements
SASB RT-CH-110a.2
- In 2019, the discharge pipeline of the first-stage outlet separation tank of the flash compressor on production line 4 was modified to reflux to the compressor inlet separation tank.
- In 2021, the discharge pipeline of the first-stage outlet separation tank of the booster compressor on production line 3 was modified to reflux to the compressor inlet separation tank.
- In 2022, plans were made to replace the old steam boiler.
- In 2025, a new Liquid-Gas Oxidizer paired with catalytic ceramic filter tubes was added, capable of treating in-plant process discharge oil and process tail gas, reducing emissions of Total Suspended Particulates (TSP), Nitrogen Oxides (NOx), and Volatile Organic Compounds (VOCs).
Air Pollutant Emissions of the Linyuan Plant in Past 3 Years:
GRI 305-7
SASB RT-CH-120a.1
Unit: MT
| Year |
NOx |
SOx |
VOCs |
HAPs |
| 2023 |
5.261 |
3.930 |
32.754 |
17.353 |
| 2024 |
5.147 |
4.261 |
21.977 |
8.231 |
| 2025 |
5.216 |
1.293 |
27.574 |
12.392 |
Explanation:
In 2025, SOx emissions per unit of product decreased compared to 2024, primarily because testing showed non-detectable (N.D.) values for SOx emissions from RTO equipment, leading to lower total SOx emissions. Conversely, VOC emissions increased significantly, mainly due to a 3.9 metric ton increase in xylene usage for equipment cleaning compared to 2024, along with higher tested VOC emission concentrations from the RTO.
Additionally, process-related Hazardous Air Pollutants (HAPs) at the Linyuan Plant consist of vinyl acetate monomer (VAM) and xylene. Currently, there is no regulatory limit for VAM. Xylene is used as a solvent for cleaning equipment rather than a required raw material in the manufacturing process, so it is not listed for regulatory control by the Ministry of Environment; its emissions totaled 12.392 metric tons.
(Restatement of Information: In 2025, xylene activity data was included in the HAP statistics, and the data for 2023 and 2024 have been updated accordingly.)
Air Pollutant Emissions per Unit of Product at the Linyuan Plant for the Past Three Years
Unit: kg/MT
Volatile Organic Compounds (VOCs)
2023 年
2024 年
2025 年
The emissions test results of the Linyuan Plant over the years have all been lower than the Emission Standards announced by the Environmental Ministry. The table below shows the 2025 emissions test results of APC's pipelines:
| Pollutant |
Unit |
Thermal Oil Boiler |
Steam Boiler |
Emission Standards |
| Nitrogen Oxides (NOx) |
ppm |
75 |
47 |
100 |
| Sulfur Oxides (SOx) |
ppm |
4 |
11 |
50 |
| Total Suspended Particulates (TSP) |
mg/Nm3 |
1 |
13 |
30 |
| Regenerative Thermal Oxidizer |
Emission Standards |
| 2 |
150 |
| 4 |
100 |
| 8 |
100 |
Note: Particulates refer to Total Suspended Particulate, abbreviated as TSP.